Reduce downtime – Find leakage currents without taking equipment offline The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned down
Reduce downtime – Find leakage currents without taking equipment offline The Fluke 369 FC true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line. The Fluke 369 FC has an oversize 61 mm jaw for work with extra-large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.
Specifications:
Measurement function: Alternating current
AC ampere range: 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection: mA / A: manual selection
Range / Resolution: 3 mA¹ / 0.001 mA
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²: 3 mA – 30 A
Frequency: 40 Hz to 1 kHz
Crest Factor: 3
Display (LCD): Digital readout: 3300 count
Display refresh rate: 4 times / sec
Maximum conductor diameter: 61 mm
Dimensions: 257 x 116 x 46 mm
Weight: 600 g
Battery: 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life: Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down: Meter automatically shuts down after 15 minutes of inactivity
General safety: IEC 61010-1: Pollution Degree 2
Measurement safety: IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature: -10 °C to +50 °C
Storage temperature: -40 °C to +60 °C
Operating humidity: Non-condensing (<10 °C)
Protection class: IEC 60529: IP30 (jaw closed)
Operating altitude: 2000 m
Storage altitude: 12000 m
Current sensor action category: IEC 61557-13: Class 2, ≤30 A / m
Group 1: Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class B: Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Class A: This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.