Welcome to WOW! Contact Us
FLUKE INFRARED THERMOMETER 62MAX +

FLUKE INFRARED THERMOMETER 62MAX +

FLUKE INFRARED THERMOMETER 64 MAX

FLUKE INFRARED THERMOMETER 64 MAX

FLUKE INFRARED THERMOMETER 568EX

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or p

Availability:
In stock
SKU
WOW-21267

The Fluke 568 Ex Intrinsically Safe Infrared Thermometer is certified by major rating bodies for use in Class I Div. 1 and Div. 2 or Zone 1 and 2 hazardous environments anywhere in the world. Whether you work in petroleum, chemical, oil and gas, or pharmaceutical environments, the 568 Ex allows you to carry the most trusted name in test tools into most Ex-rated areas around the globe. The simple, three-button on-screen menu interface is quick to use and makes even complex measurements easy. It takes just a few pushes of a button to adjust emissivity, record data, or turn on and off alarms. The 50:1 distance-to-spot ratio allows you to measure smaller objects from further away. And it also is compatible with K-type probes for contact measurements. Either way, you can count on the rugged, ergonomic design to stand up to tough conditions.

Specifications:

  • Infrared temperature range: -40°C to 800°C (-40°F to 1472°F)
  • Infrared accuracy: < 0°C (32°F): ±(1.0°C (±2.0°F) + 0.1°/1°C or°F);
  • Display resolution: 0.1°C / 0.1°F
  • Infrared spectral response: 8 µm to 14 µm
  • Infrared response time: < 500 ms
  • Thermocouple type-k input temperature range: -270°C to 1372°C (-454°F to 2501°F)
  • Thermocouple type-k input accuracy: < -40°C: ±(1°C + 0.2°/1°C)
  • D:S (distance to measurement spot size): 50:1
  • Laser sighting: Single-point laser
  • Minimum spot size: 19 mm (0.75 in)
  • Emissivity adjustment: By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
  • Data storage: 99 points
  • Hi/Low alarms: Audible and two-color visual
  • Min/Max/Avg/Dif: Yes
  • Display: Dot matrix with function menus
  • Backlight: Two levels, normal and extra bright for darker environments
  • Trigger lock: Yes
  • Switchable celsius and fahrenheit: Yes
  • Power: 2 AAA/LR03 type-approved batteries (For a list of type-approved batteries, refer to Product Safety Instructions.)
  • Battery life: 4 hours with laser and backlight on;
  • Operating temperature: 0°C to 50°C (32°F to 122°F)
  • Storage temperature: -20°C to 60°C (-40°F to 140°F)
  • Bead thermocouple type-k range: -40°C to 260°C (-40°F to 500°F)
  • Bead thermocouple type-k accuracy: ±1.1°C (2.0°F) from 0°C to 260°C (32 °F to 500°F),
Write Your Own Review
You're reviewing:FLUKE INFRARED THERMOMETER 568EX
Your Rating