Reduce downtime – Find leakage currents without taking equipment offline The Fluke 368 true-rms leakage current clamp meter helps users detect, document, record and compare leakage current readings over time as a means of preventing unplanned downtime, and identifying intermittent GFCI and RCD trips, all without taking equipment off line. The Fluke 368 has a large 40 mm diameter jaw for work with large conductors. The clamp’s jaw is fully shielded to accurately capture very small leakage signals, and to minimize external electromagnetic interference.
Specifications:
Measurement function: Alternating current
AC ampere range: 3 mA, 30 mA, 300 mA, 3 A, 30 A, 60 A
Range selection: mA / A: manual selection
Range / Resolution: 3 mA¹ / 0.001 mA
Accuracy – filter activated (40 to 70 Hz), filter off (40 to 1 kHz)²: 3 mA – 30 A
Frequency: 40 Hz to 1 kHz
Crest Factor: 3
Display (LCD): Digital readout: 3300 count
Display refresh rate: 4 times / sec
Maximum conductor diameter: 40 mm
Dimensions: 234 x 101 x 46 mm
Weight: 500 g
Battery: 2 AA, IEC LR6, NEDA 15A, alkaline
Battery life: Expected battery life, without using backlight and spotlight, is more than 150 hours
Automatic shut-down: Meter automatically shuts down after 15 minutes of inactivity
General safety: IEC 61010-1: Pollution Degree 2
Measurement safety: IEC 61010-2-032: CAT III 600 V / CAT IV 300 V
Operating temperature: -10 °C to +50 °C
Storage temperature: -40 °C to +60 °C
Operating humidity: Non-condensing (<10 °C)
Protection class: IEC 60529: IP30 (jaw closed)
Operating altitude: 2000 m
Storage altitude: 12000 m
Current sensor action category: IEC 61557-13: Class 2, ≤30 A / m
Group 1: Generated inside the equipment and / or use radio frequency energy associated with conducting the energy for the device's own internal functions is essential.
Class B: Equipment for home appliances and residential buildings directly connected to a low voltage power supply network equipment. When this device is connected to a test object, it may exceed the emission levels produced by CISPR 11 requirements.
Class A: This product meets the requirements of industrial electromagnetic equipment, vendors or users should be aware of this. This device is intended for use in a commercial environment, instead of the home environment.